Timed Keep Warm Function

Instantaneous HIU’s generally include a stand-by mode ‘keep warm’ function, which keeps the primary pipework to the HIU and the domestic hot water heat exchanger warm, to ensure a quick hot water response.

The amount of energy used to maintain this function is often underestimated and in many cases not even considered. It’s Important that the Keep Warm function is thermally controlled so that it uses a minimal amount of heat network energy.

Our Smart HIUs are electronically controlled, which means the ‘keep warm’ function can be programmed by the resident and switched off during periods of no demand. Also, this Smart Energy Regulation and Control ensures that the minimum amount of primary flow is used to accurately match the hot water temperature.

 

 

 

Keep Warm & the BESA HIU Test Standard

One of the tests under the BESA HIU standard is to Measure the return temperature with Keep Warm facility switched on. This data is used along with space heating and DHW return temperatures to calculate the overall Volume Weighted Average Return Temperature (VWART).

Real life VWART and network efficiency can be greatly improved by reducing the Keep Warm temperature settings and enabling residents to set their own schedules for the timing of the keep warm function to reflect more realistic periods of occupation.

A key feature of the Evinox ModuSat® XR’s Smart Energy Regulation and Control is its ability to provide remotely adjustable Keep Warm set points and scheduling, meaning that real life average annual return temperatures can be further reduced, with a suitable balance struck between the speed of DHW delivery for the home owner and the overall network efficiency requirements of the operator.

Find Out More About the Energy Efficiency Features of our ModuSat® Smart HIU Range

Find Out More by Downloading the ModuSat® XR Brochure using the form below – 

ModuSat XR Brochure Image
Evinox-Headers-Battersea Power Station

Heat Networks

  • District and Communal Heat Networks
  • Delivery of low carbon heating
  • Heat Interface Units
  • Energy Metering and Billing
  • Service and Maintenance
Evinox background

Energy Metering & Billing

  • Credit Billing Services
  • PaySmart® Pre-payment System
  • Billing Solutions for Non Evinox Equipment
  • Heat Network (Metering & Billing) Regulations 2014 Advice and Guidance
  • Domestic Heat Meters and Point of Entry & Bulk Meters
Evinox installed communial heating

Service & Maintenance

  • Heat Interface Unit Service & Maintenance
  • Plant Room – Planned Preventative Maintenance (PPM)
  • ModuSat® Heat Interface Unit Enhanced Warranty Cover
  • Combined Packages for Metering, Billing and Service & Maintenance
  • Domestic Boiler Service & Maintenance